141 research outputs found

    Absorption and Scattering 2D Volcano Images from Numerically Calculated Space-weighting functions

    Get PDF
    Acknowledgments Yosuke Aoki and an anonymous reviewer greatly improved the quality of the paper. All calculations were made with Mathematica-10TM. Discussions with Marie Calvet, Danilo Galluzzo, Mario La Rocca, Salvatore De Lorenzo, Jessie Mayor and Ludovic Margerin are gratefully acknowledged. The authors are supported by MEDSUV European project and by Spanish Project Ephestos, CGL2011-29499-C02-01 and NOWAVES, TEC2015-68752. The TIDES EU travel Cost action provided travel money to support cooperation between Luca De Siena and the other authors.Peer reviewedPostprin

    The 3D Attenuation Structure of Deception Island (Antarctica)

    Get PDF
    Peer reviewedPostprin

    Exercise motivational regulations and exercise addiction: The mediating role of passion

    Get PDF
    Background and aims The study explored the mediating role of forms of passion in the relationship between motivational regulations in exercise and exercise addiction (EA). Methods A total of 485 university students (368 males and 117 females; Mage = 20.43, SD = 3.21) completed a questionnaire measuring the frequency and intensity of exercise, motivational regulations in exercise, passion for exercise, and EA. Controlling the effects of age, frequency, and intensity of practice, the relationships between the study variables were examined though a path analysis. Results Both self-determined and non-self-determined forms of motivation showed positive association with EA. The forms of motivation with greatest predictive power for EA were introjected and integrated regulations. Both forms of motivation had positive direct and indirect effects through obsessive passion (OP) on EA; however, integrated regulation also showed negative indirect effects through harmonious passion on EA. Conclusions Both forms of passion and, especially, OP, seem to affect how motivational regulations are associated with EA. These findings clarify the association found in previous studies between self-determined forms of motivation and EA

    Transient out-of-SOA robustness of SiC power MOSFETs

    Get PDF
    Beyond their main function of high-frequency switches in modulated power converters, solid-state power devices are required in many application domains to also ensure robustness against a number of overload operational conditions. This paper considers the specific case of 1200 V SiC power MOSFETs and analyses their performance under three main transient regimes at the edge of and out of their Safe Operating Area: unclamped inductive switching led avalanche breakdown; short-circuit; operation as current limiting and regulating devices. The results presented highlight both inherent major strengths of SiC over Si and areas for improvement by tailored device design. The paper aims to contribute useful indications for technology development in future device generations to better match widespread and varied application requirements

    Numerically Calculated 3-D Space-Weighting Functions to Image Crustal Volcanic Structures Using Diffuse Coda Waves

    Get PDF
    Acknowledgments: This research was partly supported by the Projects TEC2015-68752 (MINECO/FEDER), TEC2015-68752 (KNOWAVES).Peer reviewedPublisher PD

    Induction of the calcineurin variant CnAβ1 after myocardial infarction reduces post-infarction ventricular remodelling by promoting infarct vascularization

    Get PDF
    AIMS: Ventricular remodelling following myocardial infarction progressively leads to loss of contractile capacity and heart failure. Although calcineurin promotes maladaptive cardiac hypertrophy, we recently showed that the calcineurin splicing variant, CnAβ1, has beneficial effects on the infarcted heart. However, whether this variant limits necrosis or improves remodelling is still unknown, precluding translation to the clinical arena. Here, we explored the effects and therapeutic potential of CnAβ1 overexpression post-infarction. METHODS AND RESULTS: Double transgenic mice with inducible cardiomyocyte-specific overexpression of CnAβ1 underwent left coronary artery ligation followed by reperfusion. Echocardiographic analysis showed depressed cardiac function in all infarcted mice 3 days post-infarction. Induction of CnAβ1 overexpression 1 week after infarction improved function and reduced ventricular dilatation. CnAβ1-overexpressing mice showed shorter, thicker scars, and reduced infarct expansion, accompanied by reduced myocardial remodelling. CnAβ1 induced vascular endothelial growth factor (VEGF) expression in cardiomyocytes, which resulted in increased infarct vascularization. This paracrine angiogenic effect of CnAβ1 was mediated by activation of the Akt/mammalian target of rapamycin pathway and VEGF. CONCLUSIONS: Our results indicate that CnAβ1 exerts beneficial effects on the infarcted heart by promoting infarct vascularization and preventing infarct expansion. These findings emphasize the translational potential of CnAβ1 for gene-based therapies.European Union [ERG-239158, CardioNeT-ITN-289600]; Spanish Ministry of Science and Innovation [BFU2009-10016, SAF2012-31451]; Regional Government of Madrid [2010-BMD-2321]; Fondo de Investigaciones Sanitarias [RD12/0042/0066]; Spanish Ministry of Economy and Competitiveness; Pro-CNIC FoundationS

    Accurate quantification of atherosclerotic plaque volume by 3D vascular ultrasound using the volumetric linear array method.

    Get PDF
    Direct quantification of atherosclerotic plaque volume by three-dimensional vascular ultrasound (3DVUS) is more reproducible than 2DUS-based three-dimensional (2D/3D) techniques that generate pseudo-3D volumes from summed 2D plaque areas; however, its accuracy has not been reported. We aimed to determine 3DVUS accuracy for plaque volume measurement with special emphasis on small plaques (a hallmark of early atherosclerosis). The in vitro study consisted of nine phantoms of different volumes (small and medium-large) embedded at variable distances from the surface (superficial vs. >5 cm-depth) and comparison of 3DVUS data generated using a novel volumetric-linear array method with the real phantom volumes. The in vivo study was undertaken in a rabbit model of atherosclerosis in which 3DVUS and 2D/3D volume measurements were correlated against gold-standard histological measurements. In the in vitro setting, there was a strong correlation between 3DVUS measures and real phantom volume both for small (3.0-64.5 mm(3) size) and medium-large (91.1-965.5 mm(3) size) phantoms embedded superficially, with intraclass correlation coefficients (ICC) of 0.99 and 0.98, respectively; conversely, when phantoms were placed at >5 cm, the correlation was only moderate (ICC = 0.67). In the in vivo setting there was strong correlation between 3DVUS-measured plaque volumes and the histological gold-standard (ICC = 0.99 [4.02-92.5 mm(3) size]). Conversely, the correlation between 2D/3D values and the histological gold standard (sum of plaque areas) was weaker (ICC = 0.87 [49-520 mm(2) size]), with large dispersion of the differences between measurements in Bland-Altman plots (mean error, 79.2 mm(2)). 3DVUS using the volumetric-linear array method accurately measures plaque volumes, including those of small plaques. Measurements are more accurate for superficial arterial territories than for deep territories.S
    corecore